The EURUS II Industrial Ceiling Fan utilizes advanced aerodynamics in Kale's Dovetail Power Blades for efficient air circulation. With a power consumption of only 1.5KW or less, it offers substantial ventilation and temperature cooling. Crafted from robust materials like forged steel and aircraft-grade aluminum, it ensures safety and longevity.
The gear motor features German LENZE technology for reduced noise, increased safety, and energy efficiency. Precision-engineered hubs guarantee dynamic balance, while the Schneider electrical sets and German control cabinets ensure top-tier safety and performance. The Dovetail Power Blades and unique connector highlight its superior design and reliability, making it an ideal solution for large-area ventilation and cooling.
The gear motor features German LENZE technology for reduced noise, increased safety, and energy efficiency. Precision-engineered hubs guarantee dynamic balance, while the Schneider electrical sets and German control cabinets ensure top-tier safety and performance. The Dovetail Power Blades and unique connector highlight its superior design and reliability, making it an ideal solution for large-area ventilation and cooling.




Specification
Size
16 ft - 24 ft
Air volume
11300m³/min - 14100m³/min
Power
1.5kW
Fan weight
74KG – 110KG
Max Speed
57RPM - 62RPM
Full Load Current
2.4Amps/380 - 5.7Amps/220V
Noise Level
<40.0dB(A)
Main Components:
Gear Motor:
Adopt an imported German LENZE motor and work with a German company to develop a geared motor for HVLS products.
1.Use low backlash assembly process and gear grinding technique, lower noise
2.Strength the bearing frame structure, increase oil seal and strength the motor structure with trapezoidal shaft structure, higher safety
3.Adopt IE2 high efficient motor, save more 5-10% than IE1
4.Passed CCC, CE, UL certificates
Adopt an imported German LENZE motor and work with a German company to develop a geared motor for HVLS products.
1.Use low backlash assembly process and gear grinding technique, lower noise
2.Strength the bearing frame structure, increase oil seal and strength the motor structure with trapezoidal shaft structure, higher safety
3.Adopt IE2 high efficient motor, save more 5-10% than IE1
4.Passed CCC, CE, UL certificates
- Use a low backlash assembly process and gear grinding technique, to lower noise.
- Strength the bearing frame structure, increase oil seal, and strengthen the motor structure with trapezoidal shaft structure, higher safety.
- Adopt IE2 highly efficient motor, save more 5-10% than IE1 4. Passed CCC, CE, and UL certificates.

Hub:
The hub is made by 1500T hot forging, numerical control machining, and CNC precise machining. Forging is able to confirm the consistency of metal structure, which can keep the inside structure and the outside shape of forged pieces consistent. The complete streamline structure of the metal confirms the best mechanical property of the hub. By CNC machining, the precision tolerance has been controlled at 100um, which guarantees the precise dynamic balance of the hub.
The hub is made by 1500T hot forging, numerical control machining, and CNC precise machining. Forging is able to confirm the consistency of metal structure, which can keep the inside structure and the outside shape of forged pieces consistent. The complete streamline structure of the metal confirms the best mechanical property of the hub. By CNC machining, the precision tolerance has been controlled at 100um, which guarantees the precise dynamic balance of the hub.

Control System:
Top level electrical configuration in HVLS industry, Schneider brand electrical sets, with building safety protection module which will shut down the output automatically in case of some accidents. International(Danfoss & Scheider)brand control cabinet, passed EMC by SGS and CCC certificates, meanwhile, passed anti-creeping tests which shields electromagnetic interference effectively. Protection level is IP55, passing UL, EMC,LVD, ROHS certificates.
Top level electrical configuration in HVLS industry, Schneider brand electrical sets, with building safety protection module which will shut down the output automatically in case of some accidents. International(Danfoss & Scheider)brand control cabinet, passed EMC by SGS and CCC certificates, meanwhile, passed anti-creeping tests which shields electromagnetic interference effectively. Protection level is IP55, passing UL, EMC,LVD, ROHS certificates.

Dovtail Power Blades:
EURUS II series fans are equipped with dovetail power fan blades, which are Kale's new generation fan blades. Low-speed operation eliminates heat accumulation on the roof and can be used in multiple seasons, which will significantly improve the air volume, wind layer, coverage, and safety performance! Core Advatages of EURUS II HVLS Fans: Large air volume, wide range, high wind layer!
EURUS II series fans are equipped with dovetail power fan blades, which are Kale's new generation fan blades. Low-speed operation eliminates heat accumulation on the roof and can be used in multiple seasons, which will significantly improve the air volume, wind layer, coverage, and safety performance! Core Advatages of EURUS II HVLS Fans: Large air volume, wide range, high wind layer!

Winglet:
The kind of empennage is always seen among airplanes and motorcycle races, but it’s not designed for beauty. Eddies will be formed in the end of the streamlined fan blade while airflow is running. With winglet, this part of energy loss will be avoided, fan will run steadily, which will bring economic effect.
The kind of empennage is always seen among airplanes and motorcycle races, but it’s not designed for beauty. Eddies will be formed in the end of the streamlined fan blade while airflow is running. With winglet, this part of energy loss will be avoided, fan will run steadily, which will bring economic effect.

Connector for Fan Blade:
KALE unique patented jacket-type connector adopt three cold forging process + magnetic force grinding process + anodic oxidation process, aviation hard aluminum 7050 aging heat treatment, certificated by the national quality inspection center, it bears more than millions of times of fatigue experiment, completely solve the break and drop problem caused by long time running!
KALE unique patented jacket-type connector adopt three cold forging process + magnetic force grinding process + anodic oxidation process, aviation hard aluminum 7050 aging heat treatment, certificated by the national quality inspection center, it bears more than millions of times of fatigue experiment, completely solve the break and drop problem caused by long time running!